Standard Cylinders :-
No Series Troubles Cause Remedy
1

A12 ISO

Cylinder does not function Low inlet pressure Increase the inlet Pressure
Piston jerks during forward stroke Leak through Nutring / Main seal (13) TEST Replace Nutring / Main seal (13)
Piston jerks during Reverse stroke Leak through the piston seal
Leak through Nutring (17)
Replace Nutring (17)
Cushion adjustment does not function Defective cushion seal (10)
Cushion piston damaged (3)
Replace Cushion seal (10)
Replace Cushion Piston (3)
Leak at Piston Rod end Defective Nutring (17)
Defective Wiper (18
Replace Nutring (17)
Check and replace Wiper (18)
2

A13 ISO

Cylinder does not function Low inlet pressure Increase the inlet Pressure
Piston jerks during forward stroke Leak through Nutring / Main seal (13) TEST Replace Nutring / Main seal (13)
Piston jerks during Reverse stroke Leak through the piston seal
Leak through Nutring (17)
Replace the O ring (5)
Replace Nutring (17)
Cushion adjustment does not function Defective cushion seal (10)
Cushion piston damaged (3)
Cushion piston damaged (3)
Replace Cushion Piston (3)
Leak at Piston Rod end Defective Nutring (17)
Defective Wiper (18
Replace Nutring (17)
Check and replace Wiper (18)